Description
Data transmission | Technical Features |
The information is sent through two cables (TX and GND)at the RS-232 interface with the following configuration: 9600 Bauds, 8 data bits, N parity, one stop bit.
The data package is sent every time the tag is detected. As long as the tag remains in the reading field, the data is continuously being sent. |
Material: Polyethylene.
Dimensions: 292 x 220 x 30 mm (L x W x H). Distance between scanners: The distance between one scanner and other must be at least 440mm. Distance from metallic objects: The distance from metallic objects must be over 120mm. Reading distance: Approximately 120mm with 30mm tags. The tags must be at least 30mm distant from metal. |